Daikin VRV W III is an individual air conditioning system that utilities water as a heat source. In this unique system, water is piped from a central cooling tower or boiler to the compact VRV W III (the equivalent of the outdoor unit in a conventional air conditioning system) and after heat exchange, refrigerant is piped from the VRV W III to each indoor unit. This unique system can perform as a heat pump or heat recovery system to suit the requirements of most commercial applications.

Water-Side Infrastructure & Components

  • A water loop system is routed around the building, either vertically or horizontally.
  • Heat Injection (Boilers) and Rejection (Cooling Tower or Dry Coolers) are required to ensure that the water loop remains between the required design conditions of 10-45°C.
  • VRV W III condensers are connected to the water loop and the connecting refrigerant circuit serves indoor units the same as any air cooled VRV system.

The following Water Side components are required:

  • Strainer (Mandatory)
  • Flow Switch or Differential Pressure Switch (Mandatory)
  • Pressure and temperature gauges
  • Circulation Pumps

Download Brochure

Sensitive Choice
Minimum Energy Performance Standards
learn more

All Daikin air conditioners exceed MEPS requirements, in line with Daikin’s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions.

VRV-WIII offers 2-stage heat recovery operation
  • Unified heat pump or heat recovery (simultaneous operation) condensing unit
  • 22kW and 27kW module condensers available that may be combined for a maximum capacity of 80kW
  • Continuous operation for cold climates, delivering comfortable heating performance with no defrost
  • Long refrigerant lines of up to 120m (linear run) and a total of 300m
  • Plate Heat Exchanger can withstand a maximum water pressure up to 30kPA (for water design water flow rate of 1.6L/s)
  • Allows for a maximum connection ratio of 130%
  • Condensers are compact 780x550x1,000mm (WxDxH), lightweight - 149kg (22kW class) and can be double-stacked to minimize spatial requirements
  • The advanced self-diagnostic auto-check function detects malfunctions, immediately displaying the fault type and location so it can be resolved quickly and effectively
  • RWEYQ condensing unit sound level as low as 50dB(A)
  • Connects to all advanced Daikin Control Solutions including I-Touch Controller and I-Touch Manager
  • Can be integrated to Open Protocol Building Management Systems via the Daikin BACnet® and LonWorks ® interfaces

 

Advanced features for easy installation and superior reliability

  • VRV W III features a pump interlock function, controlling the heat source pump in parallel
    with the starting of the VRV-WIII unit, significantly simplifying operation and management of a
    buildings air conditioning system.
  • VRV W III uses DIII-NET - Daikin's proprietary high speed transfer protocol.
    DIII-NET means all indoor units, VRV-WIII units and control systems can share common wiring, making installation easier.
  • VRV W III can also be easily connected to existing third party BMS systems via Daikin DIII Net.
  • VRV W III includes an auto address setting function and check function to detect and flag wiring and piping connection errors, for easier installation.
  • Water piping goes only to the VRV-WIII unit, with refrigerant piping run in occupied spaces.  This means there is virtually no risk of water leakage or corrosion damaging interior fit out.

Centralised interlocking function

VRV-WIII allows centralised interlocking input via an external control adaptor (DTA104A62).

By using one external control adaptor circuit board, centralised interlocking input to multiple units within the same water system is possible.

Centralised interlocking function
Easily Responds to Simultaneous Heating and Cooling Needs

By adding suction gas piping and a BS unit (sold separately), simultaneous heating and cooling operation can be provided by a single system.

Standard System(Heat Pump) StandardHeat Recovery Heat Recovery
* For indoor units used for cooling only (do not connect to BS unit when using for heat recovery), total capacity index must be 50% or less than the capacity index of the outside units.
Sensitive Choice
Secure Portal
learn more

A full range of technical and support materials, including Engineering Data, Service and Installation Manuals are available via the Daikin Secure Portal

Contact a Daikin Sales Engineer

A Daikin Sales Engineer will assess, plan and install the right air conditioning solution for you, with creativity and sensitivity to the needs of your family or business.

American Air Filter
American
Air Filter
Learn More

AAF offers a comprehensive air filtration portfolio to provide clean air solutions for commercial and industrial applications.

You appear to be using an outdated browser. Please upgrade your browser for a better experience. X
You appear to be using an outdated browser.
Please upgrade your browser for a better experience.
Upgrade your browser today